Lower-GWP direction
R454B offers a GWP of approximately 466 and zero ozone-depletion potential for approved new equipment.
A 22LB professional-use cylinder for approved R454B air-conditioning, heat-pump and chiller equipment.
A clean editorial layout for Refrigenta—focused on the product, technical clarity and the needs of HVAC professionals.

R454B offers a GWP of approximately 466 and zero ozone-depletion potential for approved new equipment.

Designed for qualified HVAC professionals following the equipment manual, SDS and all applicable A2L safety requirements.

Capacity and efficiency characteristics suited to approved residential and light-commercial comfort systems.
Zeotropic HFO/HFC blend
Disposable supply cylinder
Mildly flammable—trained handling required
About 78% lower than R410A
Non-ozone-depleting formulation
Confirm OEM requirements before service
69.9% / 31.1% nominal blend
Not a universal drop-in replacement
Compatibility must always be verified against the equipment nameplate and the original manufacturer’s documentation.
Approved mini-split, multi-split, ducted and packaged comfort systems.
Listed packaged and direct-expansion air-conditioning equipment.
Reversible heating and cooling units engineered specifically for R454B.
Compatible chillers and cooling equipment approved by the OEM.
Check the unit nameplate, manufacturer literature, refrigerant designation and required charge.
Follow the SDS, ventilate the work area and use approved recovery, charging and leak-detection equipment.
Charge and commission strictly according to manufacturer instructions and applicable regulations.
No. R454B is used in equipment specifically engineered and approved for it. Never add R454B to an R410A-only system unless the equipment manufacturer expressly permits a documented conversion procedure.
No. Mixing refrigerants can create unsafe operating conditions, compromise system performance and prevent proper recovery or recycling.
R454B is classified A2L, meaning it has lower toxicity and mild flammability. It requires trained handling, adequate ventilation and tools and procedures suitable for A2L refrigerants.
Only equipment whose nameplate and manufacturer documentation specify R454B. Common applications include approved air conditioners, heat pumps and DX chillers.
No. This listing is for a factory-sealed disposable cylinder. Handle, transport and dispose of it in accordance with applicable local and federal requirements.
Service should be performed by a qualified HVAC professional who understands A2L refrigerants and follows all licensing, certification and safety requirements applicable to the work location.
Free U.S. shipping and secure checkout from Refrigenta.