System-matched service
Use where the equipment nameplate, OEM guidance or an approved retrofit procedure specifically identifies R407C.
A 25LB professional-use cylinder for compatible R407C air-conditioning, heat-pump and refrigeration equipment.
A professional supply format focused on correct identification, liquid charging and manufacturer-approved applications.

Use where the equipment nameplate, OEM guidance or an approved retrofit procedure specifically identifies R407C.

As a zeotropic blend, R407C should be transferred and charged in liquid form to help maintain the correct composition.

Commonly specified for compatible comfort cooling, heat-pump and selected refrigeration equipment.
Zeotropic HFC blend
Disposable supply cylinder
Lower toxicity, no flame propagation
Use dew and bubble values correctly
Non-ozone-depleting formulation
Confirm OEM requirements before service
23% / 25% / 52% nominal blend
Helps prevent composition shift
Compatibility must always be verified against the equipment nameplate and the original manufacturer’s documentation.
Approved mini-split, multi-split, ducted and packaged comfort systems.
Listed packaged and direct-expansion air-conditioning equipment.
Compatible reversible heating and cooling units whose documentation specifies R407C.
Compatible chillers and cooling equipment approved by the OEM.
Check the unit nameplate, manufacturer literature, refrigerant designation and required charge.
Repair leaks, recover the existing charge and prepare the system according to the OEM procedure and applicable requirements.
Charge and commission strictly according to manufacturer instructions and applicable regulations.
No. R407C may be used in certain approved retrofit procedures, but lubricant, components and operating settings may need changes. Always follow the equipment manufacturer’s documented procedure.
No. Mixing refrigerants can create unsafe operating conditions, compromise performance and prevent proper recovery or recycling.
R407C should be removed from the cylinder and charged in liquid form because it is a zeotropic blend. Use suitable metering practices to prevent liquid damage to the compressor.
Equipment whose documentation specifies R407C, plus systems covered by a documented manufacturer-approved R407C retrofit procedure.
No. This listing is for a factory-sealed disposable cylinder. Handle, transport and dispose of it in accordance with applicable requirements.
Service should be performed by a qualified HVAC professional following the SDS, OEM documentation and all licensing, certification and safety requirements applicable to the work location.